Constructions Standards Checklists
POST-TENSIONED
FOUNDATIONS A. All plumbing, electrical and chases have been backflled and compacted in accordance with soils report and Engineer of Record (EOR) design specifcations. B. All conduit is placed at a sufficient depth below the slab so as not to impact the thickness of the slab. C. All footing trenches are clean, straight and square. D. Minimum 6 mil vapor barrier installed beneath all
slab, grade beams, and bottom of footers unless exempted by local code or EOR with all seams or cuts sealed with polypropylene tape. E. Pipes passing through concrete are protected with sleeve or wrap that allows for movement including expansion and contraction of piping. F. Vapor barrier at penetrations includes an additional 2' x 2' piece poly vapor barrier that is sealed to feld of the vapor barrier and the penetration. G. Post-tensioned cable ends are protected with caps. H. EOR is required to make spot observations of the trade contractor.
CONSTRUCTION STANDARDS CHECKLISTS | Foundations | 7