Constructions Standards Checklists
NON-STRUCTURAL FRAMING
FRAMING A. Ensure 1/8" gap between OSB (or similar product) sheathing on all 4 sides to include subfloor. B. Framing is to be 16" on center around all tub and shower walls (including knee walls). C. All subfloor, stair treads, HVAC Platforms to be minimum 23/32" OSB or equivalent, recommend subfloor adhesive in conjunction with ring shank nails or screws, installed with proper spacing/ offsets. D. Roof decking includes H-clips to ensure proper gapping. E. Cricket installed at chimneys and other penetrations of a similar shape that create a parallel line with the ridge line. The cricket must be capable of shedding water 6" beyond the corner of the fnished structure. F. Open framed corners (open framed corners
for insulation) are to be used where possible (exception due to site specifc engineering/ Municipality requirements details where this is not achievable). G. Ladder blocking at interior walls to exterior intersections is vertical, eliminating the thermal bridge from inside to out. This also allows the wall insulation to be placed behind the blocking. H. All untreated wood is protected from any masonry or concrete contact with metal plate or flashing membrane. I. Truss clip or screw (or engineered equivalent) clips properly installed with visible clearance in place for all truss to non-load bearing wall connections. Toe nailing trusses is prohibited. J. A sill sealing strategy is employed beneath all base plates on exterior walls, including the garage separation wall, at foundation contact.
CONSTRUCTION STANDARDS CHECKLISTS | Framing | 11