Constructions Standards Checklists
STRUCTURAL FRAMING
FRAMING A. Solid contact is maintained at all headers, beams, and studs down to the foundation. B. All load points are continuously transferred to the foundation. C. No alterations (holes, notches, splices, etc.) to any engineered structural component (beams, trusses, TJl's, etc.) without an engineer repair protocol. Or per manufacturer recommendations for TJl's. D. All structural and bracing details are followed per Engineer of Record (EOR)/Municipality requirements details on plans. E. All headers are installed per EOR. F. Correct nailing pattern and size of fasteners on site-built beams/girder trusses/ stud packs per EOR.
G. All hangers per EOR are installed with correct size and type of fastener. H. Hurricane clips or truss screws are in place where trusses meet exterior walls. I. All beams to be supported by full depth of wall below unless abutting beams with dimensional lumber should share the space equally. J. Any stud in an exterior wall or bearing partition shall be permitted to be cut or notched to a depth not exceeding 25 percent of its width. Studs in nonbearing partitions shall be permitted to be notched to a depth not to exceed 40 percent of a single stud width.
CONSTRUCTION STANDARDS CHECKLISTS | Framing | 13