SOLID SURFACE SHOWER STALL
SHOWERS AND TUBS A. All shower units must have a continuous, integral tiling flange that is a minimum of 1" high. No cracked or damaged flanges are permitted. B. 2x6 blocking is installed at perimeter of shower at flange height - bottom edge of blocking should be approximately 1" below top of tiling flange. C. 4" butyl based self-adhered flashing is used to seal the pan flange to the 2x6 blocking - Use “7 step approach” with 6" pieces of flashing in front and back corners and individual pieces of flashing between corners. D. Shower backerboard is installed with a factory
edge down towards shower unit and held just above top of tiling flange -backerboard should extend beyond surround area so that the joint between backer board and drywall does not align with edge of solid surface surround. E. 6" butyl tape was installed at all backerboard corners and behind seams in the solid surface surround. F. Adhesive for solid surface surround is applied in a vertical pattern to restrict sideways movement of water. G. Leave a minimum 1/8" gap between solid surface panels and shower unit for sealant. H. Pan weeps are open and clear of grout and sealant. I. All solid surface panel joints are flled with C920 Class 25 caulk at all transitions, including joints between shower pan and surround. J. Any shower seats shall have a continuous waterproofng membrane over them.
CONSTRUCTION STANDARDS CHECKLISTS | Showers & Tubs | 45