THIN PROFILE WRB SHEATHING – PENETRATIONS
DRAINAGE PLANE A. All penetrations are adequately protected with butyl flashing tape or correctly sized rigid type flashing panels and flanged components and adequately supported by the sheathing. B. Electrical wires should be sealed from the bottom and top with butyl flashing tape. C. When installed, flashing panels or flanged components are sealed to the sheathing on the sides and top. D. All flashing tape is pressed flat, provides a tight seal around the flashing panel and covers any fasteners penetrating the flashing panel. Install additional seam tape where required per manufacturer installation instructions. E. Horizontal trim pieces and ledger boards attached through the water-resistive barrier (WRB) have drip caps sealed to the sheathing and turned up or down at the ends.
34 | Drainage Plane | CONSTRUCTION STANDARDS CHECKLISTS